TGB Blade 250 ATV Quad Service Repair Manual, Page 199Get this manual

TGB Blade 250 ATV Quad Service Repair Manual, Page 199

17ELECTRICAL SYSTEM Inspection on Charging Voltage Voltmeter Ammeter Connect tachometerTurn on the headlight to high beam
the revolution of the engine exceeds the specified rpmBulbs used exceed their rate and consume too much powerThe replacement
battery is aged and does not have enough capacity(2) The charging voltage is normal, but the current is notThe replacement
battery is aged and does not have enough capacityBattery used does not have enough electricity or is over chargedThe fuse
of the ammeter is blownThe ammeter is improperly connected(3) The charging current is normal, but the voltage is notThe fuse
of the voltmeter is blown0 Caution Before conducting the inspection, be sure that the battery is fully chargedIf undercharged,
th current changes dramatically0 Use fully charged battery having voltage larger than 13.0 While starting the engine, the
starter motor draws large amount of current from the batteryI After the engine is warmed up, replace original battery with
fully charged batteryConnect digital voltmeter to the battery terminalsConnect an ammeter between both ends of the main fuse