2000 Arctic Cat ATV Factory Service Manual, Page 19Get this manual

2000 Arctic Cat ATV Factory Service Manual, Page 19

! CAUTION Do not charge the battery while it is in the ATV with the battery terminals connected On the 250300 cc, the fuses
under starter motor relayNOTE: To remove the fuse, compress the locking tabs on either side of the fuse case and lift out
6Place the battery into position in the ATV and secure with the hold-down bracket7Attach the vent tube and check the vent
tube to make sure it is not crimped or obstructed in any way and that it is properly routed through and secured to the frame8Connect
cables to the proper terminals: positive cable to the positive terminal (+) and negative cable to the negative terminal (-)Connect
the negative cable lastFig2-4 On the 400500 cc, the remaining fuses are located in fuse block next to the battery under the
seatIf there is any type of electrical system failure, always check the fuses firstFig2-6 ! CAUTION Always replace blown