2000 Arctic Cat ATV Factory Service Manual, Page 214Get this manual

2000 Arctic Cat ATV Factory Service Manual, Page 214

4Allow the oil to cool, and when the temperature is at (or just before) temperature of 140 (284 F), the meter should read
thermometer should be allowed to touch the bottom of the container or inaccurate readings will occurU se rs sw ch and thermometerFig5-9
VOLTAGE (Main Harness Connector to Fan Motor) 1Set the meter selector to the D.CVoltage position2Connect the red tester lead
to the blackred wire (the black 2-prong at the fan motor); connect the black tester lead to ground3Remove the two spade terminals
from the fan temperature switch (located on the lower left corner of the radiator); then using "jumper wire," jump the spade
wires together4The meter must show battery voltageNOTE: If the meter shows no battery voltage, troubleshoot the battery,
fuse, motor, switches, or the main wiring harnessNOTE: If the meter shows battery voltage, the main wiring harness is goodThe
connector and the switch wiring harness should be checked for resistanceRESISTANCE (Fan Motor Connector) ! CAUTION 733-554B