3With the starter button depressed, the meter must show battery voltage and the starter motor should operateFig5-50 NOTE:
to each small terminal of the solenoidThere should be an audible "click" from the relay, and the meter must show less than
ohmFig5-52 Starter Relay (250300 cc) RESISTANCE ! CAUTION Always disconnect the battery when performing resistance tests
to avoid damaging the multimeterCH100D 1Disconnect the battery; then verify that the ignition fuse is goodDisconnect all
wires from the solenoid2Set the meter selector to the OHMS position3Connect the tester leads to each of the heavy posts of
the solenoid4The meter must show an open circuit NOTE: If there was no audible "click" from the relay or if the meter shows
more than ohm, it must be replacedIf there was "click," continue to test resistance 6With the 12-volt power supply still
connected, connect the red tester lead to the heavy battery cable terminal; connect the black tester lead to the heavy starter