2000 Arctic Cat ATV Factory Service Manual, Page 232Get this manual

2000 Arctic Cat ATV Factory Service Manual, Page 232

CDI Unit (400500 cc) NOTE: As an example, connect the red tester lead to terminal #1; connect the black tester lead to terminal
in the chartFig5-56 ! CAUTION Always disconnect the battery when performing resistance tests to avoid damaging the multimeterATV-0099
1Set the meter selector to the OHMS position2Test each combination as found in the following chartWrite down each test value
for each test for comparison with the value in the chartCDI UNIT ELECTRICAL TEST SPECIFICATIONS (k-ohms) Positive Meter Lead
To: 0 5-22 15-60 1-6 2-9 5-22 5-22 24-100 5-22 5-22 9-35 10-40 11-45 11-45 11-45 11-45 22-90 26-100 0 5-22 1-7 2-9 0 5-22