RegulatorRectifier (400500 cc) Negative Meter Lead to: REGULATORRECTIFIER SPECIFICATIONS (k-ohms) Positive Meter Lead To:
in the chartFig5-57 1Set the meter selector to the D.CVoltage position2Connect the red tester lead to the orange wire; connect
the black tester lead to ground3The meter must show battery voltageNOTE: If the meter shows no battery voltage, inspect the
fuses, wiring harness, connectors, or ignition switchNOTE: In the following test, the ignition switch must be in the ON position
and the emergency stop switch must be in the RUN position REGULATORRECTIFIER TERMINALS 4With the black tester lead still
connected to ground, connect the red tester lead to the yellowgreen wire5Depress the starter buttonThe meter must show battery
voltage0735-352 NOTE: If the meter shows no battery voltage, inspect fuses, wiring harness, connectors, and switchesRESISTANCE
(RelayCopper Terminals) ! CAUTION Always disconnect the battery when performing resistance tests to avoid damaging the multimeter