PEAK VOLTAGE (250300) NOTE: All of the peak voltage tests should be made using the Fluke Model 73 Multimeter (pIn 0644-191)
may vary due to internal circuitry NOTE: The battery must be at full charge for these testsPrimaryCOl 1Connect the red tester
lead to one end of the cap; then connect the black tester lead to the other end of the cap NOTE: The COl is located beneath
the seat and fender panel near the battery 1Set the meter selector to the DCVoltage position2Connect the red tester lead
to the primary coil terminal; then connect the black tester lead to ground3Crank the engine over using the electric starter4The
meter reading must be within specificationPEAK VOLTAGE (500) 2The meter reading must be within specification NOTE: If the
meter does not read as specified, replace the spark plug cap NOTE: All of the peak voltage tests should be made using the
Fluke Model 73 Multimeter (pIn 0644-191) with Peak Voltage Reading Adapter (pIn 0644-307)If any other type of tester is used,