RESISTANCE (Charging Coil) Magneto Coils VOLTAGE (Charging CoilOutput) CAUTION Always disconnect the battery when performing
(Trigger Coil) 1Set the meter selector to the ACVoltage position2Test between the three yellow wires (250300) for total of
three tests or the three black wires (400500) for total of three tests CAUTION Always disconnect the battery when performing
resistance tests to avoid damaging the multi meter 1Set the meter selector to the OHMS position2On the 250300, connect the
red tester lead to the blackyellow wire; then connect the black tester lead to the greenwhite wireThe meter reading must
be within specification3On the 400500, connect the red tester lead to the green wire; then connect the black tester lead
to the blue wireThe meter reading must be within specificationRESISTANCE (Source Coil400500) 1Set the meter selector to the
OHMS position3With the engine running at constant 5000 RPM, all wire tests must show 60 A.Cvolts2Connect the red tester lead
to the yellow wire; then connect the black tester lead to the white wire3The meter reading must be within specification NOTE: