2003 Arctic Cat ATVs from 250cc to 500cc Service Manual, Page 411Get this manual

2003 Arctic Cat ATVs from 250cc to 500cc Service Manual, Page 411

PEAK VOLTAGE (250300) 3Crank the engine over using the electric starter4The meter reading must be within specificationMagneto
Coil (Charging) NOTE: All of the peak voltage tests should be made using the Fluke Model 73 Multimeter (pIn 0644-191) with
Peak Voltage Reading Adapter (pIn 0644-307)If any other type of tester is used, readings may vary due to internal circuitry
NOTE: The battery must be at full charge for these testsMagneto Coil (Trigger) 1Set the meter selector to the DCVoltage position2Connect
the red tester lead to one yellow wire; then connect the black tester lead to the other yellow wire3Crank the engine over
using the electric starter4The meter reading must be within specificationPEAK VOLTAGE (400) 1Set the meter selector to the
DCVoltage position2Connect the red tester lead to the green wire; then connect the black tester lead to the blue wire3Crank
the engine over using the electric starter4The meter reading must be within specificationMagneto Coil (Source) NOTE: All
of the peak voltage tests should be made using the Fluke Model 73 Multimeter (pIn 0644-191) with Peak Voltage Reading Adapter