NOTE: If the meter showed no battery voltage, inspect the main fuse, ground connections, starter motor lead, battery voltage
connect the red tester lead to the heavy battery cable terminal; then connect the black tester lead to the heavy starter
motor cable terminal7The meter must show less than ohm8With the 12-volt power supply disconnected, connect the tester leads
to each small terminal of the solenoid9The meter must show 4.3 ohms 20 NOTE: If the meter shows no resistance, the relay
is out of tolerance or it must be replaced Starter Relay NOTE: Leave the tester leads connected to the solenoid posts for
the following procedure NOTE: An external 12-volt power supply "jumper" (positive and negative connections) must be used
for this testAlso, it is very important that the meter leads and power supply connections are made to the appropriate terminals