PEAK VOLTAGE (2501300) 1Set the meter selector to the D.CVoltage position2Connect the red tester lead to the primary coil
engine over using the electric starter Power Source Reverse 4The meter reading must be within specificationPEAK VOLTAGE (400)
INOTE: All of the peak voltage tests should be made using the Fluke Model 73 Multimeter (pin 0644-191) with Peak Voltage
Reading Adapter (pin 0644-307)If any other type of tester is used, readings may vary due to internal circuitryround emperature
eutral INOTE: The battery must be at full charge for these testsPrimarylCDI I NOTE: The CDI is located beneath the seat and
fender panel near the batteryINDICATOR LIGHTS = Male Terminal Female Terminal 1Set the meter selector to the D.CVoltage position
To access the indicator light connector for testing purposes, use the following procedure1Remove the three machine screws
and key cover securing the instrument pod2Remove the light bar from the instrument pod; then cut the cable tie securing the