2Test between the three yellow wires (2501300) for total of three tests or the three black wires (4001500) for total of three
Model 73 Multimeter (pin 0644-191) with Peak Voltage Reading Adapter (pin 0644-307)If any other type of tester is used, readings
may vary due to internal circuitry 2On the 2501300, connect the red tester lead to the blacklyellow wire; then connect the
black tester lead to the greenlwhite wireThe meter reading must be within specification3On the 4001500, connect the red tester
lead to the green wire; then connect the black tester lead to the blue wireThe meter reading must be within specificationRESISTANCE
(Source Coil 4001500) INOTE: The battery must be at full charge for these testsMagneto Coil (Trigger) 1Set the meter selector
to the D.CVoltage position 2Connect the red tester lead to the green wire; then connect the black tester lead to the blue
wire3Crank the engine over using the electric starter4The meter reading must be within specificationMagneto Coil (Source)