2005 Arctic Cat ATVs factory service and repair manual, Page 512Get this manual

2005 Arctic Cat ATVs factory service and repair manual, Page 512

PEAK VOLTAGE (2501300) INOTE: All of the peak voltage tests should be made using the Fluke Model 73 Multimeter (pin 0644-191)
Fluke Model 73 Multimeter (pin 0644-191) with Peak Voltage Reading Adapter (pin 0644-307)If any other type of tester is used,
readings may vary due to internal circuitryINOTE: The battery must be at full charge for these tests 3Crank the engine over
using the electric starter4The meter reading must be within specificationMagneto Coil (Charging) 1Set the meter selector
to the D.CVoltage position2Connect the red tester lead to one yellow wire; then connect the black tester lead to the other
yellow wire Magneto Coil (Trigger) 3Crank the engine over using the electric starter4The meter reading must be within specificationPEAK
VOLTAGE (400) INOTE: All of the peak voltage tests should be made using the Fluke Model 73 Multimeter (pin 0644-191) with
Peak Voltage Reading Adapter (pin 0644-307)If any other type of tester is used, readings may vary due to internal circuitryI