3With the starter button depressed, the meter must show 0.50.7 DC volts4With the starter button released, the meter must
wire3With the switch in the OFF position, the meter must show an open circuit4With the switch in the RUN position, the meter
must show less than ohmNOTE: If the meter shows more than ohm of resistance, troubleshoot or replace the switchcomponent,
the connector, or the switch wiring harness RESISTANCE ! CAUTION Always disconnect the battery when performing resistance
tests to avoid damaging the multimeter 1Set the meter selector to the OHMS position2Connect the red tester lead to the red
wire; then connect the black tester lead to the white wire3With the selector switch in the 2WD position, the meter must show
closed circuit4With the selector switch in the 4WD position, the meter must show an open circuitNOTE: If the meter does not
show as specified, replace the front drive selector switch RESISTANCE (Reverse Override) The connector is the four-prong
white one next to the steering postTo access the connector, the front rack and front fenders must be removed (see Section