Secondary Winding 1Remove the plug cap from the high tension lead; then connect the red tester lead to the high tension lead2On
then connect the black tester lead to the other end of the cap i NOTE: The CDI is located beneath the seat near the battery
1Set the meter selector to the DC Voltage position; then disconnect the bluelwhite primary wire from the coil2Connect the
red tester lead to the primary wire; then connect the black tester lead to ground3Crank the engine over using the electric
starter4The meter reading must be within specification2The meter reading must be within specificationIf the meter does not
read as specified, replace the spark plug capi NOTE: Indicator Lights PEAK VOLTAGE (400) All of the peak voltage tests should
be made using the Fluke Model 73 Multimeter (pin 0644-191) with Peak Voltage Reading Adapter (pin 0644-307)If any other type
of tester is used, readings may vary due to internal circuitry1 NOTE: The battery must be at full charge for these tests1
NOTE: To access the indicator light connectors for testing purposes, use the following procedure 1Remove the two reinstallable