Output-to-Actuator Voltage (650 V-Twin) Speed Sensor Signal Voltage (650 V-Twin) Select DC Voltage on the multimeter (B)
the pinklwhite wire terminal (5) and the black tester lead to the black wire terkinal (10) in the controller (A) Output-to-speed
Sensor Voltage (650 V-Twin) Select DC Voltage on the multimeter (B), disconnect the speed sensor connector, and turn the
ignition switch ON; then connect the red meter lead to the pinklwhite wire terminal (5) and the black tester lead to the
black wire terminal (10) in the controller (A)The meter should read 0.25 DC voltsIf the reading is not as specified, replace
the actuator con-troller 3Spin rear wheel in the forward direction while observing the multimeterThe meter should alternately