Clutch Lever Position Switch RESISTANCE VOLTAGE (Charging CoilNo Load) NOTE: The peak voltage reading adapter must be disconnected
(pn 0644-307)If any other type of tester is used, readings may vary due to internal circuitryNOTE: The battery must be at
full charge for this test 1Set the meter selector to the AC Voltage position2Test between the three brown wires for total
of three tests PEAK VOLTAGE (Charging Coil Output) 1Set the meter selector to the DC Voltage position2Connect the red tester
lead to the positive battery post; then connect the black tester lead to the negative battery post3With the engine running
at constant 5000 RPM (with the headlights on), the meter must be within specification 3With the engine running at constant
5000 RPM, all wire tests must show 65+ AC volts ! CAUTION Do not run the engine at high RPM for more than 10 secondsNOTE:
If both charging coil tests failed, check all connections, etc and test againIf no voltage is present, replace the stator