2006 Arctic Cat DVX 400 Service Manual, Page 161Get this manual

2006 Arctic Cat DVX 400 Service Manual, Page 161

Electrical Problem: Spark absent or weak Condition 1Ignition coil defective 2Spark plug defective 3Magneto defective 4CDI
5Replace plug 6Replace seals 7Replace rings Remedy 1Replace plug 2Service cooling system 3Tighten plug 4Adjust carburetor
Remedy 1Repairreplacetighten lead wires 2Replace magneto coils 3Replace regulatorrectifier Problem: Magneto charges, but
charging rate is below the specification Condition Remedy 1Lead wires shortedopenloose (at terminals) 1Repairtighten lead
wires 2Stator coils (magneto) groundedopen 3Regulatorrectifier defective 4Cell plates (battery) defective 2Replace stator
coils 3Replace regulatorrectifier 4Replace battery Problem: Magneto overcharges Condition 1Internal battery short circuited
2Regulatorrectifier resistor damageddefective 3Regulatorrectifier poorly grounded Remedy 1Replace battery 2Replace resistor
3Cleantighten ground connection Problem: Charging unstable Condition 1Lead wire intermittently shorting 2Magneto internally