2006 Arctic Cat DVX Utility 250 Service Manual, Page 90Get this manual

2006 Arctic Cat DVX Utility 250 Service Manual, Page 90

4Allow the water to coolOn the cooling fan switch when the temperature is within range of 80-85 (176-185 F), the meter should
lift out VOLTAGE (Main Harness Connector to Fan Motor) 1Set the meter selector to the DC Voltage position2Connect the red
tester lead to the brownblue wire; then connect the black tester lead to ground3The meter must show battery voltageNOTE:
If the meter shows no battery voltage, troubleshoot the battery, fuse, or the main wiring harnessNOTE: If the meter shows
battery voltage, the main wiring harness is goodThe connector should be checked for resistanceKM102 NOTE: The ignition switch
must be in the LIGHTS position 1Remove all fuses from the fuse block2Set the meter selector to the DC Voltage position3Connect
the black tester lead to ground4Using the red tester lead, contact each end of the 30 amp fuse holder connector terminals
individually5The meter must show battery voltage from one side of the connector terminal ends6Install the 30 amp fuse; then
using the red tester lead, check the remaining two fuse holder connectors as in step 4 RESISTANCE (Fan Motor Connector) !