2006 Arctic Cat Y-6/Y-12 50cc and 90cc Service Manual, Page 71Get this manual

2006 Arctic Cat Y-6/Y-12 50cc and 90cc Service Manual, Page 71

TESTING VOLTAGE 1Disconnect the negative and positive battery terminals2Set the meter selector to the DC Voltage position3Connect
one spade end of the fuse; then connect the black tester lead to the other spade end3The meter must read less than ohm resistanceIf
the meter reads open, replace the fuseNOTE: Make sure the fuse is returned to its proper position according to amperage VOLTAGE
(Wiring Harness Connector) 1Set the meter selector to the DC Voltage position; then turn the ignition switch to the ON position2Connect
the red tester lead to the greenyellow wire; then connect the black tester lead to suitable ground3The meter must read battery
voltageNOTE: If the meter reads no battery voltage, troubleshoot the battery, fuse, switch, or the main wiring harnessNOTE:
If the meter reads battery voltage, the main wiring harness is good; test the switchcomponent, the connector, and the switch
wiring harness for resistance Ignition Coil The ignition coil is attached to the upper frame behind the left-side of the