2007 Arctic Cat ATVs 400/500/650/700 Service Manual, Page 373Get this manual

2007 Arctic Cat ATVs 400/500/650/700 Service Manual, Page 373

Fan Motor The connector is the black two-prong one located behind the fan assemblyNOTE: The ignition switch must be in the
harness is goodThe connector should be checked for resistance Fuse BlockPower Distribution Module The fuses are located in
power distribution module under the seatIf there is any type of electrical system failure, always check the fuses firstNOTE:
The ignition switch must be in the LIGHTS position 1Remove all fuses from the distribution module2Set the meter selector
to the DC Voltage position3Connect the black tester lead to ground RESISTANCE (Fan Motor Connector) ! CAUTION Always disconnect
the battery when performing resistance tests to avoid damaging the multimeter 4Using the red tester lead, contact each end
of the fuse holder connector terminals individually5The meter must show battery voltage from one side of the connector terminal
endsNOTE: Battery voltage will be indicated from only one side of the fuse holder connector terminal; the other side will