VOLTAGE (Stator CoilNo Load) The connector is the black three-pin one on the right side of the engine just above the starter
Magneto Coils (400500650 H1) 1Set the meter selector to OHMS position2Test between the three black wires for total of three
tests3The meter reading must be within specificationRESISTANCE (Trigger Coil) VOLTAGE (Stator CoilRegulated Output) 1Set
the meter selector to the DC Voltage position2Connect the red tester lead to the positive battery post; then connect the
black tester lead to the negative battery post3With the engine running at constant 5000 RPM (with the headlights on), the
meter must show 14-15.5 DC volts ! CAUTION Always disconnect the battery when performing resistance tests to avoid damaging
the multimeter 1Disconnect the gray four-pin connector on the right side of the engine just above the starter motor2Set the
meter selector to the OHMS position3Connect the red tester lead to the green wire; then connect the black tester lead to