2007 Arctic Cat ATVs 400/500/650/700 Service Manual, Page 381Get this manual

2007 Arctic Cat ATVs 400/500/650/700 Service Manual, Page 381

RESISTANCE (Source Coil) Magneto Coil (Trigger) 1Set the meter selector to the OHMS position2Connect the red tester lead
the yellow wire; then connect the black tester lead to the white wire3Crank the engine over using the electric starter4The
meter reading must be within specification Magneto Coil (Trigger) 1Set the meter selector to the DC Voltage position2Connect
the red tester lead to the green wire; then connect the black tester lead to the blue wire3Crank the engine over using the
electric starter4The meter reading must be within specificationMagneto Coil (Source) Stator CoilCrankshaft Position (CKP)
Sensor VOLTAGE (RegulatorRectifierOutput) 1Set the meter selector to the DC Voltage position2Connect the red tester lead
to the yellow wire; then connect the black tester lead to the white wire3Crank the engine over using the electric starter4The
meter reading must be within specificationPEAK VOLTAGE (500650 H1) NOTE: All of the peak voltage tests should be made using
the Fluke Model 73 Multimeter (pn 0644-191) with Peak Voltage Reading Adapter (pn 0644-307)If any other type of tester is