2007 Arctic Cat ATVs 400/500/650/700 Service Manual, Page 388Get this manual

2007 Arctic Cat ATVs 400/500/650/700 Service Manual, Page 388

Error codes can be cleared by following the procedures located in the ECU Error Codes (700 EFI) sub-section in this section
lead to the positive battery post and the black tester lead to the negative battery post3Start the engine and slowly increase
RPMThe voltage should increase with the engine RPM to maximum of 15.5 DC voltsNOTE: If voltage rises above 15.5 DC volts,
the regulator is faulty or battery connection is loose or corrodedClean and tighten battery connections or replace the regulatorrectifierIf
voltage does not rise, check Voltage (Charging CoilNo Load) in this sectionIf charging coil voltage is normal, replace the
regulatorrectifier 1Set the meter selector to the DC Voltage position2Connect the red tester lead to one wire; then connect
the black tester lead to the other wire3With the dimmer switch in the LO position, test the two outside connectors (LO beam)The
meter must show battery voltage4With the dimmer switch in the HI position, test the two inside connectors (HI beam)The meter
must show battery voltageNOTE: If battery voltage is not shown in any test, inspect the fuses, battery, main wiring harness,