2007 Arctic Cat DVX/Utility 250 ATV Service Manual, Page 91Get this manual

2007 Arctic Cat DVX/Utility 250 ATV Service Manual, Page 91

NOTE: Battery voltage will be indicated from only one side of the fuse holder connector terminal; the other side will show
If the voltage is not as specified in the above test, inspect the main wiring harness, main fuse, ignition fuse, ignition
switch, or engine stop switch 1Set the meter selector to the OHMS position2Connect the red tester lead to one spade end of
the fuse; then connect the black tester lead to the other spade end RESISTANCE ! CAUTION Always disconnect the battery when
performing resistance tests to avoid damaging the multimeterAR610D 3The meter must show less than ohm resistanceIf the meter
reads open, replace the fuseNOTE: Make sure the fuses are returned to their proper position according to amperageRefer to
the fuse block cover for fuse placement NOTE: For these tests, the meter selector must be set to the OHMS position Primary
Winding 1Remove the two spade connectors from the coil; then connect the red tester lead to either terminal and the black
tester lead to the other terminal2The meter reading must be within specificationSecondary Winding Ignition Coil The ignition