2007 Arctic Cat Y-12 90cc ATV Service Manual, Page 66Get this manual

2007 Arctic Cat Y-12 90cc ATV Service Manual, Page 66

Specifications IGNITION Spark Plug Type Spark Plug Gap Spark Plug Cap Ignition Coil Resistance CR7HSA 0.6-0.7 mm (0.024-0.028
the engine over using the electric starterThe meter must read 1.2-2.0 voltsRESISTANCE (peak voltage) 190-282 DC volts (blackyellow
to green) (no load) 16.0-19.5 AC volts 3000 RPM (yellow to white) Less than ohm (yellow to white) Magneto Coil Resistance
Choke Circuit (voltage) 4.0-5.5 AC volts (yellow to greenblack) 1Set the meter selector to the OHMS position Testing Electrical
Components All of the electrical tests should be made using the Fluke Model 73 Multimeter (pn 0644-191)If any other type
of meter is used, readings may vary due to internal circuitryWhen troubleshooting specific component, always verify first
that the fuse is good, that the bulb is good, that the connections are clean and tight, that the battery is fully charged,
and that all appropriate switches are activatedNOTE: For absolute accuracy, all tests should be made at room temperature
(approximately 68 F) 2Connect the red tester lead to the blue wire; then connect the black tester lead to suitable ground3The