MAINTENANCE 4Add Polaris Demand Drive Hub Fluid (PN 2871654) if necessary until fluid trickles outNOTE: Do not force the
the hub2Remove checkfill plug3Turn the hub to the o'clock position and drain the fluid into the drain pan4Turn wheel until
front hub fillcheck plug is in either the or o'clock position5Add Polaris Demand Drive Hub Fluid until fluid trickles outNOTE:
Do not force the fluid into the hub under pressure or seal damage may occur The exhaust pipe must be periodically purged
of accumulated carbon as follows: 1Remove the clean out plugs located on the bottom of the muffler as shown in illustration
1 Polaris Demand Drive Hub Fluid: (PN 2871654)oz (PN 2872277)2.5 gallon Clean Out Plug 2Place the transmission in neutral
and start the enginePurge accumulated carbon from the system by momentarily revving the engine several times3If some carbon
is expelled, cover the exhaust outlet and rap on the pipe around the clean out plugs while revving the engine several more
times4If particles are still suspected to be in the muffler, back the machine onto an incline so the rear of the machine