ELECTRICAL condition then the regulator will remain off, as the minimum battery requirement will not be metThe regulator
output turns offOnce tripped, the SSCBs can be reset by removing the overload or cycling the keyrun switchesThe SSCBs will
trip again if the issue causing the overload is not removedEngine Temperature Controller The engine temperature controller
has several features and two ouputs: HOT INDICATOR and FANThe engine hot output is low and sinks the indicator signal to
groundThe fan output is avtive high and sources battery power to turn on the fanThe controller's primary function is to control
the fan motorThe fan motor is turned on and off at preset resistances as determined by the engine temperature thermistorThe
FAN output is protected against short circuit and overloadIf the fan current exceeds the overload limit longer than the time
allowed for inrush, the fan will shut off and the HOT INDICATOR will turn onAfter delay, the FAN output will then reset itself
and turn on againIf the overload persists, the controller will cycle the FAN output on and off at set interval until the