ELECTRICAL CRANKING OUTPUT TEST WITH PEAK READING VOLTMETER The following peak voltage tests will measure the amount of output
part number to identify the moduleModules may have same "LR" I.Dnumber, but may have different part numbers, terminals, and
internal functionsLIMITER SPECIFICATIONS Refer to parts manual or microfiche for part number and applicationFUNCTIONLIMIT
RPM Reverse Limit3100 COMMENTS Scrambler 500 240 Watt Stroke (500) Test Connect Meter Wires To: Red on CDI connector and
ground Reading (Without Peak Reading Volt meter) 69 DCV Cranking Voltage GEAR POSITION INDICATOR SWITCH TEST Switch Continuity
TableSwitch Schematic HighNeutralReverse Switch CDI OUTPUT TEST USING PEAK READING ADAPTOR Re-connect all CDI wiresDisconnect
CDI module wire from ignition coil primary terminalConnect one meter lead to engine ground and the other to the ignition
coil primary wire leading from the CDI moduleCrank engine and check output of CDI wire to coilReconnect coil wire to CDI