2011 Polaris Ranger RZR ATV Service Manual, Page 350Get this manual

2011 Polaris Ranger RZR ATV Service Manual, Page 350

ELECTRICAL GENERAL INFORMATION Special Tools Part Number PV-43568 PV-43526 2870630 PU-50338 2460761 2871745 Tool Description
resistance specifications When measuring resistance ofa component that has resistance value under 10 Ohms, remember to subtract
meter lead resistance from the readingConnect the leads together and record the resistanceThe resistance of the component
is equal to tested value minus the lead resistance Become familiar with the operation of your meterBe sure leads are in the
proper jack for the test being performed (i.e10A jack for current readings)Refer to the Owner's Manual included with your
meter for more information Voltage, amperage, and resistance values included in this manual are obtained with FlukeTM 77
Digital Multimeter (PV-43568)This meter is used when diagnosing electrical problemsReadings obtained with other meters may
differ Pay attention to th prefix on the multimeter reading (K, M, etc and the position of the decimal point For resistance