ELECTRICAL STARTING SYSTEM Troubleshooting Starter Motor Does Not Run Battery discharged Loose or faulty battery cables or
gear or starter motor gear Faulty flywheel gearor loose flywheel 12Remove the starter from the engineRemove the two bolts,
washers, and sealing O-RingsInspect O-Rings and replace if damaged Voltage Drop Test The Voltage Drop Test is used to test
for bad connectionsWhen performing the test, you are testing the amount of voltage drop through the connectionA poor or corroded
connection will appear as high voltage readingVoltage shown on the meter when testing connections should not exceed 0.1 VDC
per connection or componentTo perform the test, place the meter on DC volts and place the meter leads across the connection
to be testedRefer to the voltage drop tests on the starter system in this chapter Voltage should not exceed .1 DC volts per