1999-2004 Suzuki King Quad LT-300 300F ATV Factory Service Manual, Page 258Get this manual

1999-2004 Suzuki King Quad LT-300 300F ATV Factory Service Manual, Page 258

ELECTRICAL SYSTEM SERVICING Visually inspect the surface of the battery containerIf any signs of cracking or electrolyte
battery from the vehicle to protect the regulatorirectifier against excessive voltage Use the following formula to correct
the specific gravity reading to 20C (68F)S20St +0.0007 (t-20) Where S20corrected value of specific gravity (20C or 68F) Stvalue
of specific gravity read at temperature tO 0.0007temperature coefficient of specific gravitytemperature in degrees centigrade
at which st was read Check the corrected specific gravity reading with the chart to determine the recharging time in hoursThis
is when constant-current charge at rate of 1.2 amperes (which is tenth of the capacity of the present battery) is used When
recharging, do not allow the electrolyte temperature to exceed 45C (113 Interrupt the operation, as necessary, F)to let the