2003-2005 Suzuki LT-A500F Service Manual, Page 319Get this manual

2003-2005 Suzuki LT-A500F Service Manual, Page 319

ELECTRICAL SYSTEM Repeat the above procedure few times and measure the highest pickup coil and power source coil peak voltageTester
with the peak volt adaptors followsPickup coil: Probe.Green lead wire Probe.Blue lead wire Power source coil: Probe.Yellow
lead wire Probe.White lead wire Measure the pickup coil and power source coil peak voltage in the same manner as on the CDI
unit couplerTester knob indication: Voltage () Pickup coil peak voltage: More than 4.0 Power source coil peak voltage: More
than 0.3 V Generator Peak volt adaptor Pickup coil If the peak voltage on the generator coupler is within the specification,