ELECTRICAL SYSTEM SERVICING Visually inspect the surface of the battery containerIf any signs of cracking or electrolyte
the caps on the top of the batteryRecharging time: 1.4 for to 10 hours or for hourBe careful not to permit the charging current
to exceed at any timeAfter recharging, wait at least 30 minutes and then measure the battery voltage using the multi circuit
testerIf the battery voltage is less than 12.5 V, recharge the battery againIf the battery voltage is still less than 12.5
after recharging, replace the battery with new oneWhen battery is left unused for long time, its voltage needs to be regularly
measuredWhen the vehicle is not used for more than one month (especially during the winter season), measure the battery voltage