PERIODIC MAINTENANCE Remove the valve inspection caps 3 NOTE: Valve clearance is to be checked when the engine is coldThe
bring it into the specified range Valve clearance (when cold) IN: 0.03 .08 mm (0.001 0003 in) EX: 0.08 .13 mm (0.003 0005
in)09900-20803: Thickness gauge or 09900-20804: Thickness gaugeSecurely tighten the locknut after completing adjustment#
Valve clearance adjuster locknut: 14 Nm (1.4 kgf-m, 10.0 lb-ft) Install the spark plug, valve timing inspection plug and
generator cover cap to the specified torque of each# Spark plug: 18 Nm (1.8 kgf-m, 13.0 lb-ft) Valve timing inspection plug: