ELECTRICAL SYSTEM Step 1) Measure the generator no-load performance( Is the generator no-load performance OK? Go to Step
BATTERY CURRENT LEAKAGE Remove the seat( 5-4) Turn the ignition switch to the OFF position Disconnect the batterylead wire
Measure the current betweenbattery terminal and the battery lead wire using the multi-circuit testerIf the reading exceeds
the specified value, leakage is evident09900-25008: Multi-circuit tester set Tester knob indication: Current, 20 mA) Battery
current (leak): Under mA In case of large current leak, turn the tester to high range first to avoid tester damage Do not