Charging System: Repair Instructions Battery Current Leakage Inspection Inspect the battery current leakage in the following
the tester to high range first to avoid tester damage Do not turn the ignition switch ON when measuring currentSpecial tool0990025008
(Multi-circuit tester set) Tester knob indication Current, 20 mA) Battery current (Leak) Under 1.0 mA I827H11A0032-01 3)
Measure the DC voltage between the (+) and () battery terminals using the multi-circuit testerIf the voltage is not within
the specified value, inspect the generator and regulatorrectifierRefer to "Generator Inspection (Page 1J-4)" and "RegulatorRectifier
Inspection (Page 1J-10)"NOTE When making this test, be sure that the battery is in fully charged conditionSpecial tool0990025008
(Multi-circuit tester set) Tester knob indication Voltage) Regulated voltage (Charging output) Standard: 13.5 15.0 at 000