1984 Johnson Evinrude 2 thru V-6 Service Repair Manual P/N 394607, Page 233Get this manual
Quality of the image is intentionally reduced!
7 To test for shorts, calibrate the ohmmeter to high ohm scaleConnect the black meter lead (-) to the timer base Attach the red meter lead (+) to the "A" terminal, then "B," then "C," then "0," jumper