1994 Johnson/Evinrude "ER" 9.9 thru 30 outboards Service Manual, Page 297Get this manual

1994 Johnson/Evinrude "ER" 9.9 thru 30 outboards Service Manual, Page 297

Starter Circuit Check Chart, 2030 Remote , INotel Battery must be fully charged Procedure Remove black lead from ground at
CD and INotel Steps thru Turn key OFF before connecting and disconnecting meterTurn key to START position after connecting
bIf no reading, go to Step Check voltage between ground and Connect meter at Turn key to START position aIf meter reads battery
voltage, solenoid is faultybIf no reading, go to Step Check voltage between ground and Connect meter at Turn key to START
position aIf meter reads battery voltage, lead is open between and or neutral start switch is open or improperly adjusted
bIf no reading, go to Step Check voltage between ground and Connect meter at Turn key to OFF position aIf meter reads battery