9 DR4047 STEPSENSOR COIL TEST Ground Test 1Disconnect 5-pin and 4-pin Amphenol connectors between timer base and power pack2Set
TestOutput Test 1Set peak-reading voltmeter to "POS" and "5", "SEN" and "5" on Stevens CD-77 meterf101 2Attach voltmeter
black lead to port timer base connector, terminal "E"Alternately, attach voltmeter red lead to the remaining four port and
four starboard connector terminals3Crank engine and observe meter at each connection If meter shows 0.5 volt or higher, go
to STEPPOWER PACK TEST If meter shows less than 0.5 volt, check condition of wiring and connectors If wiring and connector