1994 Johnson Evinrude "ER" 90 LV 120 thru 140, 185 thru 225, 250, 300 Service Manual P/N 500612, Page 163Get this manual

1994 Johnson Evinrude "ER" 90 LV 120 thru 140, 185 thru 225, 250, 300 Service Manual P/N 500612, Page 163

9 DR4670 DR4671 STEPCHARGE COIL TEST Ground Test f81 1Disconnect the stator's forward (cylinders 1, 3, 5) and rear (cylinders
Step using stator's rear 2-pin connector5If no reading is indicated in Steps or 4, go to Output TestOutput Test 1Set peak-reading
voltmeter to "POS" and "500" 2Attach voltmeter black lead to the stator's forward connector, terminal "A"Attach meter red
lead to terminal "B" 3Crank engine and observe meter If meter shows 130 volts or higher, go to STEPSENSOR COIL TEST If meter
shows less than 130 volts, check condition of wiring and connectors If wiring and connector condition is good, go to Ohmmeter