12 DR4061 STEPSENSOR COIL TEST Ground Test the two 4-pin Amphenol connectors between the timer base and power pack 2Set peak-reading
"A", "8", and "8"and "C"3Crank engine and observe meter at each connection If meter shows 0.2 volt or higher, go to Step
If meter shows less than 0.2 volt, check condition of wiring and connectors If wiring and connector condition is good, go
to Ohmmeter Test4Connect the "0" terminals in the separated port timer base connector using jumper wireConnect the "0" terminals
in the separated starboard timer base connector using jumper wire and port connector, terminals "A", 1141 5Attach the voltmeter
black lead to clean engine groundAttach meter red lead alternately to 6Crank engine and observe meter at each connection
If meter shows 1.2 rolts or higher, go to STEPPOWER PACK TEST If meter shows less than 1.2 volts, check condition of wiring