Sensor Coil Ohmmeter Test All ohmmeter tests must be performed with engine not running G5l 1Before proceeding, you must verify
terminals "A", "B", and "C"Meter reading at each connection should be: Stevens AT-101 meter: 360 30 ohms Merc-O-Tronic M-700
meter: 970 100 ohms Internal timer base components cause this reading to vary with individual meter impedanceYour readings
may be slightly higher or lower, but should all be approximately equalf171 5Attach ohmm'eter red lead to port timer base
connector, terminal "0"Attach meter black lead to starboard timer base connector, terminal "0" Meter should read 230 30 ohmsf181
6To test for grounded condition, connect ohmmeter alternately between each port and starboard terminal location and clean