STEPCHARGE COIL TEST Ground Test 1sl 1Disconnect the stator's forward (cylinders thru 8) and rear (cylinders thru 4) 2-pin
using stator's rear 2-pin connector5If no reading is indicated in Steps or 4, go to Output TestOutput Test 1Set peak-reading
voltmeter to "POS" and "500" 2Attach voltmeter black lead to stator's forward connector, terminal "A"Attach meter red lead
to terminal "B" 3Crank engine and observe meter If meter shows 130 volts or higher, go to STEPSENSOR COIL TEST If meter shows
less than 130 volts, check condition of wiring and connectors If wiring and connector condition is good, go to Ohmmeter Test4Repeat