STEPSENSOR COIL TEST Ground Test 1Disconnect the two 5-pin Amphenol connectors between the timer base and power pack2Set
"A", "B", "C", and "0" and port connector, terminals "A", "BII, "C", and "DlI3Crank engine and observe meter at each connection
If meter shows 0.2 volt or higher, go to Step If meter shows less than 0.2 volt, check condition of wiring and connectors
If wiring and connector condition is good, go to Ohmmeter Test f,;4J 4Connect the "E" terminals in the separated port timer
base connector using jumper wireConnect the "E" terminals in the separated starboard timer base connector using jumper wire
14 5Attach the voltmeter black lead to clean engine groundAttach meter red lead alternately to starboard connector, terminals"
A", "B", "C", and "0" and port connector, terminals "A", "B", "C", and "0"6Crank engine and observe meter at each connection