1994 Johnson Evinrude "ER" 90 LV 120 thru 140, 185 thru 225, 250, 300 Service Manual P/N 500612, Page 178Get this manual

1994 Johnson Evinrude "ER" 90 LV 120 thru 140, 185 thru 225, 250, 300 Service Manual P/N 500612, Page 178

Sensor Coil Ohmmeter Test All ohmmeter tests must be performed with engine not running r:j5l 18efore proceeding, you must
connector, terminals "A", "8", "C", and "D"Meter reading at each connection should be: Stevens AT-101 meter360 30 ohms Merc-O-Tronic
M-700 meter: 970 100 ohms Internal timer base components cause this reading to vary with individual meter impedanceYour readings
may be slightly higher or lower, but should all be approximately equalterminal "E"Attach meter black lead to starboard timer
base connector, terminal "E" Meter should read 160 20 ohmsf18l 6To test for grounded condition, connect ohmmeter alternately
between each port and starboard terminal location and clean engine ground Meter must show high reading If meter shows low