Starter System Voltage Drop Test By making systematic check of the starter system, any component or electrical connection
leads only while the engine is cranking; or damage to the voltmeter can occur2Connect voltmeter negative lead to the starter
side of the starter solenoid terminalWhile cranking engine, connect voltmeter positive lead to starter solenoid opposite
terminalVoltage reading should not exceed 0.2 voltRemove voltmeter positive lead from starter solenoid and stop cranking
engine Isl 3Connect voltmeter positive lead to starter solenoid, starter t.J lead terminalConnect voltmeter negative lead
to starter motor terminalTurn key switch to STARTVoltage reading should not exceed 0.2 volt1sl 4Connect voltmeter positive