Key Switch Check Ohmmeter or Continuity Light 1Disconnect battery leads and leads at the key switch f81 2With key switch
"A" to "s" terminalLight or meter should still show continuity r:J2l 6Transfer leads to "M" terminalsLight or meter should
not show continuity to START or ON positionskey show continuity r:J3l 7Turn to OFF positionLight or meter should 1141 8Transfer
leads to "B" and "e" terminalsTurn key switch to ON position and push in keyLight or meter should show continuity when key