Routine Inspections 1.jl 1Check reservoir fluid level at least once per season or every 50 operating hoursSystem capacity
Loosely install fill plugCycle unit in ten second spurts (adding fluid as needed)A minimum of five complete cycles is required
to purge air from the system2Look for indications of internal fluid leakageCorrect the cause if leaks are noted ill release
valve by tightening the screw to torque of 45-55 inIbs(5-6 Nm)4Inspect the stern brackets for binding with swivel bracket