10 DR4077 STEPSENSOR COIL TEST Ground Test 1Disconnect 5-pin Amphenol connector between the timer base and power pack2Set
coils or leads are grounded Locate and repair ground, or replace timer base4If no reading is indicated in Step 3, go to Output
TestOutput Test 1Set peak-reading voltmeter to "POS" and "5", "SEN" and "5" on Stevens CD-77 meterf1112Attach voltmeter black
lead to timer base connector, terminal "E"Alternately, attach voltmeter red lead to terminals "A", "8", "C", and "0"3Crank